Review





Similar Products

94
MedChemExpress intravascular dye
Intravascular Dye, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular dye/product/MedChemExpress
Average 94 stars, based on 1 article reviews
intravascular dye - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

90
Nissen intravascular ultrasound
Intravascular Ultrasound, supplied by Nissen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular ultrasound/product/Nissen
Average 90 stars, based on 1 article reviews
intravascular ultrasound - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Specific Diagnostics intravascular ultrasound
Intravascular Ultrasound, supplied by Specific Diagnostics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular ultrasound/product/Specific Diagnostics
Average 90 stars, based on 1 article reviews
intravascular ultrasound - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation intravascular ultrasound opticross hd
Angiography and <t>IVUS</t> During PCI PCI before (A) and after (B) balloon angioplasty, mechanical thrombectomy, and IVUS-guided deployment of a second layer of Synergy XD (Everolimus DES with bioabsorbable polymer). (A) RAO/CAU pre-PCI of OM1 with visualization of old stent and thrombosis (red circle). (B) RAO/CAU post-PCI of OM1 with additional stent. IVUS showed areas of neo-atherosclerosis and neo-calcification. Although the original stent was well apposed, it appeared undersized (2.5-2.75 mm). (C) Pre-PCI IVUS showing minimal stent area of 1.61 mm 2 . (D) Post-PCI IVUS showing improved minimal stent area to 6.6 mm 2 . (E) IVUS shows proximal vessel reference diameter of 3.75 mm. (F) IVUS shows distal vessel reference diameter of 3.25 mm (G) Thrombus removed from OM1. CAU = caudal; DES = drug-eluting stent; IVUS = intravenous <t>ultrasound;</t> PCI = percutaneous coronary intervention; RAO = right anterior oblique.
Intravascular Ultrasound Opticross Hd, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular ultrasound opticross hd/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
intravascular ultrasound opticross hd - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
NanoBiomed Inc targeted drugeluting intravascular nanotherapy
Angiography and <t>IVUS</t> During PCI PCI before (A) and after (B) balloon angioplasty, mechanical thrombectomy, and IVUS-guided deployment of a second layer of Synergy XD (Everolimus DES with bioabsorbable polymer). (A) RAO/CAU pre-PCI of OM1 with visualization of old stent and thrombosis (red circle). (B) RAO/CAU post-PCI of OM1 with additional stent. IVUS showed areas of neo-atherosclerosis and neo-calcification. Although the original stent was well apposed, it appeared undersized (2.5-2.75 mm). (C) Pre-PCI IVUS showing minimal stent area of 1.61 mm 2 . (D) Post-PCI IVUS showing improved minimal stent area to 6.6 mm 2 . (E) IVUS shows proximal vessel reference diameter of 3.75 mm. (F) IVUS shows distal vessel reference diameter of 3.25 mm (G) Thrombus removed from OM1. CAU = caudal; DES = drug-eluting stent; IVUS = intravenous <t>ultrasound;</t> PCI = percutaneous coronary intervention; RAO = right anterior oblique.
Targeted Drugeluting Intravascular Nanotherapy, supplied by NanoBiomed Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/targeted drugeluting intravascular nanotherapy/product/NanoBiomed Inc
Average 90 stars, based on 1 article reviews
targeted drugeluting intravascular nanotherapy - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation intravascular ultrasound (ivus) opticross hd plus 60mhz coronary imaging catheter
<t>Intravascular</t> <t>Ultrasound</t> Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.
Intravascular Ultrasound (Ivus) Opticross Hd Plus 60mhz Coronary Imaging Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular ultrasound (ivus) opticross hd plus 60mhz coronary imaging catheter/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
intravascular ultrasound (ivus) opticross hd plus 60mhz coronary imaging catheter - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
St Jude Medical fd-oct system dragonflytm oct intravascular imaging
<t>Intravascular</t> <t>Ultrasound</t> Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.
Fd Oct System Dragonflytm Oct Intravascular Imaging, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fd-oct system dragonflytm oct intravascular imaging/product/St Jude Medical
Average 90 stars, based on 1 article reviews
fd-oct system dragonflytm oct intravascular imaging - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Philips Healthcare intravascular ultrasonography eagle eye platinum
<t>Intravascular</t> <t>Ultrasound</t> Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.
Intravascular Ultrasonography Eagle Eye Platinum, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular ultrasonography eagle eye platinum/product/Philips Healthcare
Average 90 stars, based on 1 article reviews
intravascular ultrasonography eagle eye platinum - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Abiomed Inc intravascular blood pumps impella® 2.5 heart pump
<t>Intravascular</t> <t>Ultrasound</t> Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.
Intravascular Blood Pumps Impella® 2.5 Heart Pump, supplied by Abiomed Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/intravascular blood pumps impella® 2.5 heart pump/product/Abiomed Inc
Average 90 stars, based on 1 article reviews
intravascular blood pumps impella® 2.5 heart pump - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


Angiography and IVUS During PCI PCI before (A) and after (B) balloon angioplasty, mechanical thrombectomy, and IVUS-guided deployment of a second layer of Synergy XD (Everolimus DES with bioabsorbable polymer). (A) RAO/CAU pre-PCI of OM1 with visualization of old stent and thrombosis (red circle). (B) RAO/CAU post-PCI of OM1 with additional stent. IVUS showed areas of neo-atherosclerosis and neo-calcification. Although the original stent was well apposed, it appeared undersized (2.5-2.75 mm). (C) Pre-PCI IVUS showing minimal stent area of 1.61 mm 2 . (D) Post-PCI IVUS showing improved minimal stent area to 6.6 mm 2 . (E) IVUS shows proximal vessel reference diameter of 3.75 mm. (F) IVUS shows distal vessel reference diameter of 3.25 mm (G) Thrombus removed from OM1. CAU = caudal; DES = drug-eluting stent; IVUS = intravenous ultrasound; PCI = percutaneous coronary intervention; RAO = right anterior oblique.

Journal: JACC Case Reports

Article Title: 17 Years Not Too Late

doi: 10.1016/j.jaccas.2025.103871

Figure Lengend Snippet: Angiography and IVUS During PCI PCI before (A) and after (B) balloon angioplasty, mechanical thrombectomy, and IVUS-guided deployment of a second layer of Synergy XD (Everolimus DES with bioabsorbable polymer). (A) RAO/CAU pre-PCI of OM1 with visualization of old stent and thrombosis (red circle). (B) RAO/CAU post-PCI of OM1 with additional stent. IVUS showed areas of neo-atherosclerosis and neo-calcification. Although the original stent was well apposed, it appeared undersized (2.5-2.75 mm). (C) Pre-PCI IVUS showing minimal stent area of 1.61 mm 2 . (D) Post-PCI IVUS showing improved minimal stent area to 6.6 mm 2 . (E) IVUS shows proximal vessel reference diameter of 3.75 mm. (F) IVUS shows distal vessel reference diameter of 3.25 mm (G) Thrombus removed from OM1. CAU = caudal; DES = drug-eluting stent; IVUS = intravenous ultrasound; PCI = percutaneous coronary intervention; RAO = right anterior oblique.

Article Snippet: Imaging • Intravascular Ultrasound (Opticross HD, Boston Scientific).

Techniques: Polymer

Intravascular Ultrasound Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.

Journal: JACC Case Reports

Article Title: Coronary Rupture Right After Intravascular Lithotripsy for Severely Calcified Coronary Lesion With C-CAT Sign

doi: 10.1016/j.jaccas.2025.103750

Figure Lengend Snippet: Intravascular Ultrasound Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.

Article Snippet: After the 1.5-mm semicompliant balloon dilatation, an intravascular ultrasound (IVUS) (Opticross HD Plus 60MHz Coronary Imaging Catheter; Boston Scientific) was performed ( , ). shows the severe calcification at the distal bifurcation of the diagonal branch along with C-type calcified and residual thin plaque sign (C-CAT sign).

Techniques: